PFPower failure
Power was interrupted during a cycle.
Cause: Brief outage or loose plug.
Fix: Press Start to resume. If frequent, check the outlet and breaker.
What each Maytag appliance error code means, the usual cause, and the fix. Always unplug the appliance before inspecting parts.
Power was interrupted during a cycle.
Cause: Brief outage or loose plug.
Fix: Press Start to resume. If frequent, check the outlet and breaker.
Washer took over 8 minutes to drain.
Cause: Clogged drain pump filter or kinked hose.
Fix: Clean the pump filter, straighten the drain hose, check it is not pushed more than 20 cm into the standpipe.
Lid could not lock.
Cause: Obstruction, faulty lid lock or wiring.
Fix: Clear the latch area, cycle power for 1 minute; replace the lid lock if it repeats.
Water did not reach level in time.
Cause: Low water pressure, closed tap or clogged inlet screens.
Fix: Open both taps fully, clean the inlet hose screens, check hoses for kinks.